Comments on: Intelligent Building of the Week: Adam Joseph Lewis Center for Environmental Studies /2014/11/07/intelligent-building-of-the-week-adam-joseph-lewis-center-for-environmental-studies-2/?utm_source=rss&utm_medium=rss&utm_campaign=intelligent-building-of-the-week-adam-joseph-lewis-center-for-environmental-studies-2 Just another Contentive Editorial Sites site Tue, 09 Jun 2015 23:06:00 +0000 hourly 1 http://wordpress.org/?v=4.0.1 By: Thomas_Avit /2014/11/07/intelligent-building-of-the-week-adam-joseph-lewis-center-for-environmental-studies-2/#comment-145 Mon, 10 Nov 2014 21:58:00 +0000 /?p=4949#comment-145 Leighann,

Thanks for the 8/11/10 linked article, “Living machine University environmental studies building hopes to create more energy than it consumes”, with the more in-depth discussion of the building’s energy efficiency. However, I did find it surprising and disappointing that a 2010 review of a 2000 building didn’t use any updated information.

As the building was opened in 2000, I am viewing it with 14 years of “hindsight” in an industry that has advanced quite dramatically in that time span. Why such an old building was featured in a 2014 article, I view as being inappropriate as well as confusing for the general public with what is known today. An up-to-date evaluation of the building would be much more appropriate, however, I doubt that it could ever be as glorified as what has been presented thus far.

None-the-less, the article is what has been given to us, so I will justify my earlier comments with what we have to work with including a lot of information from your link.

Buried and given little weight at the end of your link are the facts that the building was projected to use 63,609 Kwh a year. Actual performance showed the building using 184,380 Kwh of energy through the first 10 months of operation – – a whopping 3.6 times as much energy as projected. As the 3,700 square feet of PV panels were expected to collect about 64,500 Kwh of solar energy annually – – that leaves a shortfall of 167,700 Kwh. Of course, adding 9,620 SF of PV panels to the existing 3,700 SF would make up for the shortfall (13,320 SF total), but I doubt that that many panels would fit on the roof of a two story building with 13,600 SF of floor space. This paragraph alone fully justifies my earlier comment.

I was also surprised that an electric boiler was even considered & specified to supply heat for the radiant coils in the atrium instead of utilizing the mega (24 geothermal wells!) geothermal heating system. Even more telling is the fact that they want to replace the electric boiler with a more energy-efficient natural-gas boiler.

Regarding the building’s R-21 walls and R-30 roof: The walls barely meet today’s IECC-2012 “minimum” standard of R-20 and the roof is way beneath the “minimum” requirement of R-49. That building as built would probably be against code in many areas of our country today. The overhanging eaves on the south wall are not particularly necessary, but they sure are on the east elevation shown in the picture where none are noted.

I am making the assumption that the building was slated for LEED certification, as “sustainability” is mentioned in both articles. This is no surprise, as LEED has minimally promoted building envelope energy efficiency, while it does promote all of the other sustainable bells and whistles that were mentioned. Unfortunately, given LEED’s visibility, many LEED certified buildings have proven to be energy hogs.

Why am I taking the time for such a lengthy critique? Because it is very inappropriate to promote a 14-yearold building as “Intelligent Building of the Week” in 2014, when the building is not built to even today’s minimum energy codes and should certainly not be featured the way it has been.

Architecturally interesting for sure, but not a good example for energy efficiency. It will never create more energy than it consumes, as your link professes.

]]>
By: Leighann_Morris /2014/11/07/intelligent-building-of-the-week-adam-joseph-lewis-center-for-environmental-studies-2/#comment-144 Mon, 10 Nov 2014 15:06:00 +0000 /?p=4949#comment-144 Hi Thomas. Thanks for the comment. I found this article pretty useful when reading about this building: http://www.bdcnetwork.com/living-machine. It has a load of information about the building’s energy efficient features!

]]>
By: Thomas_Avit /2014/11/07/intelligent-building-of-the-week-adam-joseph-lewis-center-for-environmental-studies-2/#comment-143 Mon, 10 Nov 2014 14:52:00 +0000 /?p=4949#comment-143 Pretty, I will agree and probably why it won so many architectural awards. However, as a passive solar and energy efficient building designer for the last 36 years, I cannot fathom how an Ohio building envelope with that much glass facing in so many directions offers any high level of energy efficiency. I only see high heating needs in cold seasons and high cooling needs in warm seasons. Fancy features to help to address these issues may help, but there are a lot of basic design negatives to overcome.